• Şerifali Mah. Hendem Cad. No:38 D:2 Ümraniye/İstanbul

Programma Sverker750 Test Cihazı

Manufacturer Programma
Model Sverker 750                                

The SVERKER 750 features a multi-mode display which makes relay testing more efficient. In addition to time, voltage and current, impedance (Z), resistance (R), reactance (X), virtual power (S), active power (P), reactive power (Q), phase angle (φ) and power factor (cos φ) can also be displayed.

As standard, the Megger SVERKER 750 can test directional protective equipment due to an inbuilt variable voltage source, as well as protective devices which automatically reclose after operation.

Three phase protective equipment can be also tested, albeit one phase at a time. This being said, multiple SVERKER units can be connected and syhcronized to form a basic three phase test set, applicable for relay protection systems that require phase shifting.

Relays Which The SVERKER 750 Can Test:

  • Overcurrent relays, Ansi Number 50
  • Inverse time overcurrent relays, Ansi Number 51
  • Undercurrent relays, Ansi Number 37
  • Ground fault relays, Ansi Number 50N, 51N
  • Directional overcurrent relays, Ansi Number 67
  • Directional ground fault relays, Ansi Number 67N
  • Overvoltage relays, Ansi Number 59
  • Undervoltage relays, Ansi Number 27
  • Directional power relays, Ansi Number 32
  • Power factor relays, Ansi Number 55
  • Differential protection (differential circuits), Ansi Number 87
  • Distance protection equipment (phase by phase), Ansi Number 21
  • Negative sequence overcurrent relays, Ansi Number 46
  • Motor overload protection, Ansi Number 51/66
  • Automatic reclosing devices, Ansi Number 79
  • Tripping relays, Ansi Number 94
  • Voltage regulating relays
  • Underimpedance relays, Ansi Number 21
  • Thermal relays, Ansi Number 49
  • Time-delay relays

Additional Features:

In addition to protective relay testing, the Programma SVERKER 750 also offers the following features:

  • Plotting excitation curves
  • Current and voltage transformer ratio tests
  • Burden measurement for protective relay test equipment
  • Impedance measurement
  • Efficiency tests
  • Polarity (direction) tests
  • Injection
  • Maintained - Injection continues without any time limitation.
  • Momentary - Injection continues only as long as the button is kept depressed.
  • Max. time - Injection stops automatically when the preset maximum time is reached.
  • Filtering
  • When filtering is selected, five successive readings are averaged. The following can be filtered: Current, Voltage and Extra items that are measured.
  • Off delay
  • The turning off of generation can be delayed after tripping throughout a specified time interval that is expressed in mains frequency cycles.
Product Options
programma ragnar 25

Programma Ragnar 25

Phase SHITTER Test Device

twpd-2623

TWPD-2623

Portable PD Detector

bagela bha200/10

Bagela BHA200/10

Hydraulic Cable Pusher

himalayal

Himalayal

Yüksek Gerilim Test Cihazı

skf cmas 100-sl

SKF CMAS 100-SL

Noise Meter

skf tmrt 1

SKF TMRT 1

Laser Tachometer Device